Bitoriano Etxea: Passivhaus Plus home

Description Praxis has carried out Passivhaus Plus certification for this semi-detached single-family home in Bitoriano, Álava, designed by architect and Passivhaus Designer Marçal Bonadona Berdala. The house has two floors with a treated floor area of 117 m². Built with a lightweight timber frame system, the walls have 24 cm of external insulation, 14.5 cm …

Bitoriano Etxea: Passivhaus Plus home

Passivhaus Certification

Praxis cabecera proyectos

Description

Praxis has carried out Passivhaus Plus certification for this semi-detached single-family home in Bitoriano, Álava, designed by architect and Passivhaus Designer Marçal Bonadona Berdala.

The house has two floors with a treated floor area of 117 m². Built with a lightweight timber frame system, the walls have 24 cm of external insulation, 14.5 cm between the structure and 4.5cm in the service void. The roof has a total of 28.5 cm of insulation. Ecoven Plus S82 windows were used, along with argon filled low-emissivity triple glazing.

The ventilation system includes a WOLF CWL-2 325 heat recovery unit. Heating and cooling is provided by a radiant floor system with support from fan coils, powered by a Panasonic Aquarea KIT-ADC09JE5C-1 heat pump, which also produces domestic hot water.

The home achieved a blower door test result of n50 = 0.4 air changes per hour (ACH).

On the roof, 13 photovoltaic panels have been installed, generating around 6,000 kWh/year.

Links:

PEP (Plataforma Edificación Passivhaus)

iPHa (Base de datos internacional de proyectos Passivhaus)

Photos: Marçal Bonadona

  • Year: 2022
  • Location: Calle Iturribide, Bitoriano (Álava), Spain
  • Architecture: Marçal Bonadona Berdala
  • Services provided by Praxis: Passivhaus Certification
  • Passivhaus Certification Class: Passivhaus Plus
  • Climate zone: Warm Temperate
  • Floor area: 117 m2
  • Thermal envelope area: 498 m2
  • Blower Door Result: 0,4 n50
  • Heating Demand: 14 kWh/m2·a
  • Cooling Demand: 3 kWh/m2·a
  • Primary Energy Renewable consumption (EPR): 39 kWh/m2·a
  • Final Energy consumption: 32 kWh/m2·a
  • Renewable energy generation: 55 kWh/m2·a
  • CO2eq emissions: 17 kg/m2·a