Blower Door test in Llerona
Description Blower Door airtightness test to the EN 13829 (A/B) standard for the verification of whole building airtightness, as part of the construction of a single-family home in Llerona, Barcelona. The house is an nZEB designed by Divers Arquitectura. Two tests were carried out: during construction and following completion. For the preliminary test, leaks were …
Blower Door test in Llerona
Blower Door
Description
Blower Door airtightness test to the EN 13829 (A/B) standard for the verification of whole building airtightness, as part of the construction of a single-family home in Llerona, Barcelona.
The house is an nZEB designed by Divers Arquitectura.
Two tests were carried out: during construction and following completion. For the preliminary test, leaks were detected with a handheld smoke generator and anemometer.
The final result of N50=0,83/h, is well below the minimum requirements of the Spanish building regulations CTE DB HE-1 2019.
Year: 2021
Location Llerona, Barcelona
Services: Blower Door