Borda Nova, Andorra: Multifamily Passivhaus

Description Public development with 44 social housing units, designed by architects Pau Iglesias Rodríguez and Jacint Gil Rodríguez, with Oliver Style of Praxis Resilient Buildings as Passivhaus certifier. The building is located in the city of Andorra La Vella, the capital city of Andorra. The project has a treated floor area of 3350 m2 and …

La Borda Nova, Andorra: Multifamily Passivhaus

Passivhaus Certification, thermal bridge calculations

Praxis cabecera proyectos

Description

Public development with 44 social housing units, designed by architects Pau Iglesias Rodríguez and Jacint Gil Rodríguez, with Oliver Style of Praxis Resilient Buildings as Passivhaus certifier. The building is located in the city of Andorra La Vella, the capital city of Andorra.

The project has a treated floor area of 3350 m2 and includes 228 parking places, ground floor commercial premises and a roof garden.

Alongside the certification of the building, Praxis is carrying out Passivhaus component certification of the Butech (Porcelanosa) prefabricated construction system which is being installed on the façade of the building.

Links:

PEP (Plataforma Edificación Passivhaus)

iPHa (Base de datos internacional de proyectos Passivhaus)

Fotos & renders: Locubsa; Pau Iglesias y Jacint Gil

  • Year: 2024
  • Location: Andorra La Vella, Andorra
  • Architecture: Pau Iglesias Rodríguez – Jacint Gil Rodríguez
  • Services provided by Praxis: Passivhaus Certification, thermal bridge calculations
  • Passivhaus Certification Class: Passivhaus Classic
  • Climate zone: Warm Temperate
  • Floor area: 3350 m2
  • Thermal envelope area: 4796 m2
  • Blower Door Result: 0,6 n50
  • Heating Demand: 17 kWh/m2·a
  • Cooling Demand: – kWh/m2·a
  • Primary Energy Renewable consumption (EPR): 70 kWh/m2·a
  • Final Energy consumption: 78 kWh/m2·a
  • Renewable energy generation: 0 kWh/m2·a
  • CO2eq emissions: 17 kg/m2·a

Els Guiamets: Wine cellar and tasting room

Description Energy consultancy and M&E design for a wine cellar and tasting room in the Priorat region, Tarragona, designed by architect Èlia Vaqué. The winery consists of two modules, one underground, where wine is aged, and another above ground, where tastings are held: a total of 290 m2 gross floor area. Praxis has undertaken a thermodynamic …

Els Guiamets: Wine cellar and tasting room

Energy consultancy, M & E engineering

Praxis cabecera proyectos

Description

Energy consultancy and M&E design for a wine cellar and tasting room in the Priorat region, Tarragona, designed by architect Èlia Vaqué.

The winery consists of two modules, one underground, where wine is aged, and another above ground, where tastings are held: a total of 290 m2 gross floor area.

Praxis has undertaken a thermodynamic and daylighting study of the buildings, using DesignBuilder (EnergyPlus & Radiance), assessing temperature and relative humidity conditions in the wine cellar and analysing the risk of summer overheating in the tasting room. The results have been used in the design of the thermal envelope. We’ve also designed the M & E systems: mechanical ventilation with heat recovery, space heating and cooling, hot water production, and off-grid solar PV with batteries and backup generator. 

Year: 2021

Location: Els Guiamets, Tarragona 

Services:
Thermodynamic simulation, daylighting analysis, M&E design

Multi-family building in El Carmel 

Description Energy consultancy for a multi-family building in El Carmel, a neighbourhood in the north of Barcelona, designed by Vora Arquitectura studio. This 544 m2 building, has a ground floor and 6 upper floors, on a sloped site in Mount Carmel. Each floor has one or two apartments, with a total of 7 units.  Praxis …

Multi-family building in El Carmel

Energy consultancy

Praxis cabecera proyectos

Description

Energy consultancy for a multi-family building in El Carmel, a neighbourhood in the north of Barcelona, designed by Vora Arquitectura studio.

This 544 m2 building, has a ground floor and 6 upper floors, on a sloped site in Mount Carmel. Each floor has one or two apartments, with a total of 7 units. 

Praxis has delivered the thermodynamic simulation in Design Builder (EnergyPlus), focusing on the analysis and optimization of passive systems: analysis of solar gains, optimization of thermal insulation and bioclimatic buffer zone balcony spaces. The modelling helped us deliver the thermal and airtight envelope specification, window and shading systems specification, including a study of the impact of heat recovery in the ventilation system on energy demands.

Praxis also undertook an embodied energy study, comparing the carbon footprint and costs of different construction assemblies for external walls, with the aim of choosing an economically viable, energy efficient and sustainable solution. 

Year: 2021

Location: Barcelona

Services: Thermodynamic simulation   

Trerethern Farm, Cornwall: Passive house

Consultoría energética para una vivienda unifamiliar de nueva construcción de 400 m2 en Padstow, Cornwall, Reino Unido.

Trerethern Farm, Cornwall: Passive house

Energy consultancy, M & E engineering

Praxis cabecera proyectos

Description

Energy consultancy and M&E engineering for a new build 400m2 single-family home in Padstow, Cornwall, UK. Praxis has carried out the design of the thermal envelope and the airtight and vapour control layer, together with dynamic hygrothermal analysis using the WUFI tool for the assessment of risk from moisture damage.  We’ve also undertaken analysis and calculation of construction details for the reduction of thermal bridges, verification of compliance with the UK Building Regulations BR Part L1A, advice on low-environmental impact materials, and design and specification of M & E systems: mechanical ventilation with heat recovery, space heating, hot water production, and solar PV.

Year: 2021

Location: Padstow, Cornwall, UK

Services:
Energy consultancy, thermal envelope design, airtightness and vapour control strategy, dynamic hygrothermal calculation with WUFI for assessment of risk from moisture damage, MVHR specification, heating and DHW system specification, solar PV system specification